Operating manual - English
Fig. 31
- close the protective shield. Press START.
- start automatic calibration of the clamp by electrical contact.
the display will show:
At the end of the operation the following message will appear (e.g.):
Press [ENTER] to save the data automatically adjusted.
Attention: if the [STOP] key is pressed the new calibrations will be lost and only the previous calibrations will
remain valid.
- if this is not so, the display will show an error message:
In this case the procedure MUST be repeated, carefully following all the steps described; in particular
check the positioning of the clamp (Ch. 4.4, page 18).
Wrong positioning can throw out the calibration.
Note: the calibrations will be accepted only if the variations remain within a range of -40 or +40 hundredths of a mm
(-0.0157" / +0.0157").