Operating manual - English
Enter the cuts, e.g:
Use
[down arrow key] to go on to Axis 2.
Press ENTER to continue with the cutting operation. The display will show:
Raise the safety shield, loosen the handle (N) (fig. 27, page 19) and turn the depth regulating (O) dial
so that the number 5 is aligned with the reference notch on the spindle support (you should hear a click).
Lock the lever (N).
Loosen the handle (N) by one turn and pull the anatomic grip (F2) towards the operator. This releases
the clamp, which should be slid to the right.
Release the anatomic grip, move the clamp manually, and the positioning device will lock the clamp into
the clamp reference notch. When the clamp is in position (Clamp A) tighten the handle (N).
Turn the (F) knob to the left. Fit the key to be cut into jaw A so that it lies flat on the clamp with the tip
up against Stop 2 (to do this turn the Stop 1 plate left and downwards).
Secure the key by turning the (F) knob to the right. Lower the safety shield.
If the number of keys to be cut is different from 1, use the alphanumerical keys on the keyboard to enter
the number of keys required (pieces) [1-255].
Cutter H101 is standard on the machine. If the cutter is replaced, gauge it (Ch. 5.6.2, page 39) before
proceeding.
Attention: if the U111 tracer point is used the operator must make sure the cutter has been installed because
there is no electronic device to signal any errors!
If the protective shield is not closed, the following message appears:
When the shield is lowered, the following message appears:
Press START to continue.
28
A x i s : 1 o f : 2
S i d e s : A B
1 2 3 2 4 3
( 1 2 3 4 5 6 )
A x i s : 2 o f : 2
S i d e s : A B
2 4 5 4 6 4
( 1 2 3 4 5 6 )
C l a m p : A
P o s . : 2
C u t t e r : H 1 0 1
D i a l : 5
K e y o n s i d e A
P c s = 1 / 1
[ S T A R T ]
C l o s e
s h i e l d !
C o n t i n u e ?
N o = S T O P
Ye s = S TA R T
Copyright Silca 2006
[ 6 ]
[ 6 ]
TRI-CODE H.S.