The electronic control board has exceeded the maximum permitted temperature. Check the cooling fan
(see Ch. 7.1 "Trouble shooting", page 69).
Shows that the fuse has cut out due to a short circuit in an inlet or outlet (see Ch. 7.1 "Trouble shooting",
page 69).
Signals a short circuit in port P (IN/OUT) (see Ch. 7.1 "Trouble shooting", page 69).
Shows that the fuse has cut out (see Ch. 7.1 "Trouble shooting", page 69).
Signals a fault on the electronic control board.
Signals that during the decoding cycle the decoder (U111DC) or tracer point (U111) cannot leave the
reading path because the electric contact has detected an obstacle.
Solution:
- Carefully clean the clamp of swarf or other foreign objects.
- Check that there are no obstacles around the key.
- Release the lever and turn the graduated dial to a higher position (turn to the left).
Signals that during decoding, cutting, gauging or machine clearance the machine has found an
anomalous contact along the optimum path set. Check the position of the clamp, key and template.
A L A R M 4
T E M P E R A T U R E
T u r n t h e
m a c h i n e o f f !
A L A R M 5
I / O P O W E R
C h e c k
f u s e F 4 !
A L A R M 6
D I G I T A L O U T L E T
T u r n t h e
m a c h i n e o f f !
A L A R M 7
C U T T E R M O T O R
C h e c k
f u s e F 1 !
A L A R M 8
C U T T E R M O T O R
M o t o r c i r c u i t
a n o m a l y !
A L A R M 9
F o u n d o b s t a c l e
c a n n o t c o n t i n u e !
S e e o p e r a t i n g m a n u a l .
A L A R M 1 0
F a u l t y c o n t a c t m a d e !
P r e s s S TA R T t o m o v e
a x i s a t z e r o p o i n t !