Routine And Planned Maintenance; In General; Routine Maintenance; Ordinary Maintenance - OEM TL 105 Manual De Uso

Horno para pizza
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

TL 105 - TL 108
Functioning
Chapter 6
6.1 - ROUTINE AND PLANNED MAINTE-
NANCE
6.1.a- In general
DANGER
All maintenance operations shall be car-
ried out when the oven is off and cool and
the cutout switch is disconnected, on "
" OFF position.
Maintenance operations have been subdivided into
three categories:

• ROUTINE MAINTENANCE:

It includes all the maintenance works to be made on
the machine everyday.
• PLANNED MAINTENANCE:
It includes all the maintenance works to be made ac-
cording to a maintenance plan in order to ensure a
correct working of the machine.
• MAINTENANCE IN CASE OF NEED:
Some operations to be carried out in case of need,
for instance the replacement of broken or worn com-
ponents.
6.1.b - Ordinary maintenance
6.1.b.a - Self-cleaning cycle (Fig. 1)
The oven is provided with automatic pyrolysis program.
Use the knob and point to the "
function.
A screen will appear showing the chamber temperature
(1), which must reach 400°C before the 20-minute count-
down starts as shown in field (2).
The oven will switch off automatically at the end of this
time.
To end this function, simply point to the specific exit icon
(3) with the knob.
To accelerate the cleaning process and pre-
vent needless waste of electrical energy, it is
recommended to carry out automatic clean-
ing with the movable flaps fully lowered.
Should you switch off the oven before the
end of the cleaning cycle, the cleaning pro-
gram will restart automatically once you turn
again the oven on.
• The following day to the cleaning cycle, it is possible
to brush the refractory.
FIG. 1
2
" icon to activate this
IMPORTANT
IMPORTANT
1
EN - 35
3
Tabla de contenido
loading

Este manual también es adecuado para:

Tl 108

Tabla de contenido