1 English
No.
d1-20
Intermediate Speed 1
RUN
d1-21
Intermediate Speed 2
RUN
d1-22
Intermediate Speed 3
RUN
d1-23
Releveling Speed
RUN
d1-24
Inspection Operation Speed
RUN
d1-25
Rescue Operation Speed
RUN
d1-26
Leveling Speed
RUN
d1-28
Leveling Speed Detection Level
d1-29
Inspection Speed Detection Level Sets the speed reference level at which the drive detects inspection speed when d1-18 = 0 or 3 [Speed Reference
E1-01
Input AC Supply Voltage
E1-04
Maximum Output Frequency
E1-05
Maximum Output Voltage
E1-06
Base Frequency
E1-07
Mid Point A Frequency
E1-08
Mid Point A Voltage
E1-09
Minimum Output Frequency
E1-10
Minimum Output Voltage
E1-13
Base Voltage
Expert
E2-01
Motor Rated Current (FLA)
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-04
Motor Pole Count
E2-05
Motor Line-to-Line Resistance
E2-06
Motor Leakage Inductance
E2-11
Motor Rated Power
F1-01
Encoder 1 Pulse Count (PPR)
F1-05
Encoder 1 Rotation Selection
F1-50
PG-F3 Option Encoder Type
F1-52
Serial Encoder Comm Speed
Expert
H1-01 - H1-10
Term S1 to S10 Function
Selection
H2-01
Term M1-M2 Function Selection
H2-02
Term M3-M4 Function Selection
H2-03
Term M5-M6 Function Selection
H2-04
Term P1-C1 Function Selection
H2-05
Term P2-C2 Function Selection
H3-01
Terminal A1 Signal Level Select
28
Name
Sets the intermediate speed reference when an MFDI terminal set for H1-xx = 51 [MFDI Function Selection =
Intermediate Speed] is active.
Sets the intermediate speed reference when MFDI terminals set for H1-xx = 50, 51, and 52 [MFDI Function Selection
= Nominal Speed, Intermediate Speed, and Releveling Speed] are active.
Sets the intermediate speed reference when MFDI terminals set for H1-xx = 51 and 52 [MFDI Function Selection =
Intermediate Speed and Releveling Speed] are active.
Sets the releveling speed reference when an MFDI terminal set for H1-xx = 52 [MFDI Function Selection =
Releveling Speed] is active.
Sets the inspection operation speed when an MFDI terminal set for H1-xx = 54 [MFDI Function Selection =
Inspection Operation] is active.
Sets the speed reference when an MFDI terminal set for H1-xx = 55 [MFDI Function Selection = Rescue Operation]
is active.
Sets the speed reference when an MFDI terminal set for H1-xx = 53 [MFDI Function Selection = Leveling Speed] is
active.
Sets the speed reference level at which the drive detects leveling speed when d1-18 = 0 or 3 [Speed Reference
Selection Mode = Multi-speed Mode1 (d1-01 to 08) or Multi-speed Mode2 (d1-02 to 08)]. If the selected speed
reference is lower than this parameter, the drive uses the leveling speed as the speed reference.
Selection Mode = Multi-speed Mode1 (d1-01 to 08) or Multi-speed Mode2 (d1-02 to 08)]. If the selected speed
reference is between d1-28 [Leveling Speed Detection Level] and this parameter, the drive uses the inspection speed
as the speed reference, and activates the inspection operation sequence.
Sets the drive input voltage.
Sets the maximum output frequency for the V/f pattern.
Sets the maximum output voltage for the V/f pattern.
Sets the base frequency for the V/f pattern.
Sets a middle output frequency for the V/f pattern.
Sets a middle output voltage for the V/f pattern.
Sets the minimum output frequency for the V/f pattern.
Sets the minimum output voltage for the V/f pattern.
Sets the base voltage for the V/f pattern.
Sets the motor rated current in amps.
Sets motor rated slip.
Sets the no-load current for the motor in amps when operating at the rated frequency and the no-load voltage.
Sets the number of motor poles.
Sets the line-to-line resistance for the motor stator windings.
Sets the voltage drop from motor leakage inductance when the motor is operating at the rated frequency and rated
current. This value is a percentage of Motor Rated Voltage.
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
Sets the number of output pulses for each motor revolution.
Sets the output sequence for the A and B pulses from the encoder, assuming that the motor is operating in the up
direction.
0: Pulse A leads in Up Direction, 1: Pulse B leads in Up Direction
Sets the type of encoder connected to the PG-F3 option.
0: EnDat Sin/Cos, 1: EnDat Serial Only, 2: HIPERFACE
Sets the communication speed between the PG-F3 option and the serial encoder.
0: 1M/9600bps, 1: 500k/19200bps, 2: 1M/38400bps
Sets the functions for MFDI terminals S1 to S10.
Sets the function for MFDO terminal M1-M2.
Sets the function for MFDO terminal M3-M4.
Sets the function for MFDO terminal M5-M6.
Sets the function for MFDO terminal P1-C1.
Sets the function for MFDO terminal P2-C2.
Sets the input signal level for MFAI terminal A1.
0: 0-10V (Lower Limit at 0), 1: -10 to +10V (Bipolar Reference)
Description
YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction