YASKAWA LA700 Serie Instrucciones De Instalación Y Funcionamiento página 13

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 160
Nameplate
A - Hardware revision
B - Weight
C - Drive software version
D - The address of the head office of
Yaskawa Electric Corporation
E - Accreditation standards
F - Surrounding air temperature
Rated Output Current
Table 1.1
and
Table 1.2
gives the rated output current values.
Note:
• These output current values are applicable for drives that operate at standard specifications.
• Derate the current in applications that increase the carrier frequency.
Model
2022
2031
2041
2059
2075
2094
2110
2144
2181
2225
YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction
Figure 1.1 Nameplate Information Example
Table 1.1 Three-Phase AC 200 V Class
Maximum Applicable Motor Output
kW
3.7
5.5
7.5
11
15
18.5
22
30
37
45
G - Protection design
H - Serial number
I - Lot number
J - Output specifications
K - Input specifications
L - Drive model
Continuous Rated Output Current
A
15.3
21.9
28.9
41.1
52.5
65.6
77.0
100.6
126.9
157.5
1 English
*1
50% ED Output Current
A
21.9
31.3
41.3
58.8
75.0
93.8
110.0
143.8
181.3
225.0
*1
13