Berner BHFL 33 Instrucciones De Manejo página 9

(EN)
STOP button
The loading process can be interrupted at any time by pressing the "Stop" key and answering the confirmation query in the
affirmative, and the display jumps to the basic menu.
Unplugging the mains plug from the socket also switches off the charger.
Always stop charging before removing the battery cables to avoid sparking when the charging clamps are removed.
If you interrupt the charging process of a battery mounted in a vehicle, the battery cable must always be removed from the
chassis first and only then the other battery cable.
BOOST CHARGE 12V OR 12 + 24V
The BOOST CHARGE stage is used for fast initial charging of lead batteries. The battery is charged with the maximum
charging current of the respective BHFL battery charger.
Care must be taken that the battery does not become hot when charging with the boost function!
If the battery becomes too hot, stop BOOST CHARGING and select EASY CHARGING as the battery does not seem to be
able to store the high current. The battery should have at least a nominal capacity of 80 Ah.
All functions and display options are analogous to the EASY LOAD function.
9
loading