Hilti NURON VC 4LX-22 Manual Del Usuario página 27

Ocultar thumbs Ver también para NURON VC 4LX-22:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
VC 4MX-22
VC 4HX-22
A warning tone sounds if the air speed in the suction hose drops below 20 m/s.
In order to ensure that the acoustic warning is emitted correctly, the hose diameter setting must be
set to the diameter of the suction hose in use.
3.10
Filter cleaning
WARNING
Injury to respiratory system due to dust loading! System applications (particularly grinding, cutting and
slitting) and the SafeSet application can cause considerable dust loads.
▶ Operate the product in system applications and the SafeSet application only with automatic filter cleaning
activated.
The filter cleaning system functions only when a suction hose is connected.
The vacuum cleaner has manual and automatic filter cleaning that removes most of the dust adhering to the
filter element.
Automatic filter cleaning can be switched off by pressing the "Automatic filter cleaning" button and switched
back on by pressing the button again.
Status
LED lights.
LED doesn't light.
The filter cleaning system is activated automatically each time the vacuum cleaner is switched on.
The filter element is cleaned automatically by a blast of air (a pulsating noise is heard).
In order to maintain continuously high suction power, in system applications (especially grinding and
sanding, cutting and slitting) or when collecting large quantities of dust, automatic filter cleaning must
be activated.
Independently of automatic filter cleaning, you can clean the filter at any time by pressing the "Manual filter
cleaning" button.
Power cleaning: To achieve maximum power for filter cleaning, press the "Manual filter cleaning"
button while at the same time keeping the end of the hose closed.
4
Technical data
4.1
Product properties
Unless otherwise stated, the values are applicable for all model variants.
Weight
Max. volume flow rate
Max. vacuum
Air temperature
Filter cleaning
Power input
*2416651*
Meaning
The filter cleaning system is active.
The filter cleaning system is not active.
8.9 kg
(19.6 lb)
(in accordance with EPTA-Procedure 01 with large
container, without battery)
Turbine
67 ℓ/s | 241 m³/h | 142 cfm
Hose end
30 ℓ/s | 108 m³/h | 64 cfm
17 kPa
(2 psi)
−10 ℃ ... 40 ℃
(14 ℉ ... 104 ℉)
Automatic, time-controlled
750 W
(1.01 hp)
2416651
English
23
loading

Este manual también es adecuado para:

Nuron vc 4mx-22Nuron vc 4hx-22