3.4 Control switch
Symbol
3.5 Automatic filter cleaning
The appliance is equipped with a filter cleaning system for fine dust. The filter is cleaned automatically every
7.5 seconds by a blast of air.
4 Technical data
Note
For details of the rated voltage, current, frequency and/or input power, please refer to the appliance's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at
least twice the rated input power shown on the rating plate of the appliance. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the appliance.
Weight
Mains connection (type)
Maximum volumetric flow rate (air)
Container capacity
Water capacity
Suction hose connector (C-DN/C-ID)
Vacuum (max.)
Ambient temperature (max.)
Automatic filter cleaning, all
Protection class
Protection class
5 Before use
CAUTION
Risk of injury presented by the appliance running away out of control. The vacuum cleaner may
run away out of control if the wheel brakes are not engaged.
▶ Engage the wheel brakes so that the vacuum cleaner stands securely.
Printed: 22.02.2017 | Doc-Nr: PUB / 5334131 / 000 / 00
Meaning
Switching on
Switching off
Switching on, with filter cleaning
VC 300-17 X
63.1 lb
(28.6 kg)
SJTWA 3/14 AWG
2 x 157 CFM (2 x 74 ℓ/s)
17 liq. gal
US
(65 ℓ)
13 liq. gal
US
(48 ℓ)
1.6 in
(40 mm)
3.7 psi
(254 mbar)
104 ℉
(40 ℃)
7.5 s
I
IPX4
English
5