SPIDER MAX 500
13. TESTING PROCEDURE
This is a procedure very useful for a quick and reliable testing of the equipment inputs and the speedometer movement.
To access the procedure follow the rules indicated below:
• Disconnect the equipment from the motorcycle battery.
• Connect the testing cable to ground (line no. 23)
• Restore the connection to the battery.
At this point, the system performs a display check by switching on the pixels, not all together, but line by line (each line
made of 4 elements). When the testing is over, the system prompts the operator to insert the unit of measurement and,
after displaying the "Malaguti" logo and the motorcycle icon, shows the current speed and the total covered distance
(TOD). The functions cannot be scrolled and, every time that the button is pressed, the system checks for the operation
of the leds (all leds, except the immobilizer led) and the speedometer. The latest covers all the scale travel (from the zero
to the full scale value) and back. The testing routine ends when the equipment switches to the sleep mode. Whenever the
key switch is moved to the to "ON" position again, the system switches to the standard operation mode, even if the
testing cable is still connected to ground.
14. ELECTRICAL CHARACTERISTICS
General operating characteristics
Param.
Characteristic
No.
PM1
Max. operating voltage
PM2
Operating temperature
PM3
Max power generated by PIN 16
PM4
Max power that can be applied to inputs
PM5
Max power that can be applied to outputs
General operating characteristics
Param.
Characteristic
No.
PO1
Supply voltage
PO2
Operative Temperature
PO3
Power consumption on the "ON" position
with all the leds on (Battery voltage=12,5V)
PO4
Power consumption on the "ON" position
with all the leds on (Battery voltage=12,5V)
PO5
Power consumption in Sleep mode
(Battery voltage=12,5V)
(1) This parameter represents the minimum value of voltage that can be applied to the input without affecting the
equipment operation. When said value is reached the optoelectronics components of the system (warning leds and
backlight) are off.
All manuals and user guides at all-guides.com
Ion_leds
19
Icon
Min.
VMAX
¾
TSto
-20
IHall
IInMax
¾
IoutMax
¾
Icon
Min.
Typ.
VDD
6.0 (1)
12,0
TOp
-20
¾
Ion
¾
¾
¾
¾
Islp
¾
¾
12/04
A
Max
Units
17
V
+85
°C
20
mA
20
mA
20
mA
Max
Units
16.0
V
+80
°C
470
mA
120.2
mA
1
mA