Remove the 2 fastening screws A and B to adjust the disc.
Hold it by the handle and turn the disc until reaching the desired hole (this example is: 6).
Replace screws A and B.
Back doser adjustment
After, adjustment the disc, let's adjust the back doser.
Consult the spreading table again and in the last column, it displays the back doser opening position.
See the following instructions:
1) Look on the desired flow on the table (in our example: 170 kg/hectare or the closest approximate
amount to it).
PRODUCT: URIC ACID
LEVER
POSITION
2) In the last column, you find the back doser
opening (in this example: 6).
Count 6 holes from the left to the right and
install the lever in the specified hole. Insert the
cotter pin.
22
HANDLE
SPECIFIC WEIGHT: 777 Kg M³
TRACTOR SPEED
Instructions Manual
USEFUL WIDTH: 13 M
BACK
DOSER
POSITION