Check the battery condition, the acid level and acid density

– The battery manufacturer's maintenance instructions apply.
– Check the battery housing for cracks and any spilled acid.
– Remove any oxydation remains from the battery terminals and apply an acid-free
grease to the battery terminals.
– Unscrew the stops and check the acid level.
The acid level should be at least 10-15 mm / 0.39-0.59 inches above the top of the
plates. Now close the stops.
– If necessary, re-charge the battery.