Operating Conditions - Jungheinrich ETR 314 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Electromagnetic compatibility (EMC)
The manufacturer confirms compliance with the limit values for electromagnetic
interference and interference resistance and electrostatic discharge testing as set out
in the table below:
Interference resistance
The following limit values apply for industrial trucks / transportation systems:
Environmental phenomenon
1.1
1.2
1.3
*
The frequency range was expanded to include the low-frequency
interference in the wiring.
NOTICE
Very strong electromagnetic fields can adversely affect the performance of
the industrial truck. In the same way, machinery that is highly sensitive to
electromagnetic fields may also be adversely affected by the industrial truck.
Be sure that emitted interference from the industrial truck cannot interfere
with the operation of adjacent machinery.
NOTICE
Electrical or electronic components and their configuration may not be
modified without the prior written approval of the manufacturer.
3.5

Operating conditions

Ambient temperature:
- during operation:
NOTICE
Industrial trucks intended for use in environments with temperatures below
41 °F (5 °C) or in refrigerated warehouses with extreme temperature or
humidity variations require special equipment and approval.
Frequency
Electromagnetic field
Amplitude modulation
Frequency
Electromagnetic field
Pulse modulation
Discharge static
electricity
- operating at -13 °F (-25 °C) to 104 °F (+40 °C)
Test value
27-1000 *
10
V/m (unmodulated, rms)
80
900 ± 5
10
V/m (unmodulated, rms)
50
% operating cycle
200
Repetition frequency Hz
4 contact
kV (discharge voltage)
8 air
discharge
Unit
MHz
% AM (1 kHz)
MHz
D 13