8 Error messages and troubleshooting
All repairs must be performed by authorized DeguDent personnel only.
Only qualifi ed electricians are allowed to open the unit and to work on electrical components.
Disconnect the power cord before opening the unit.
Any problems you cannot localize must be resolved by authorized DeguDent personnel only.
When shipping the unit, please follow the Moving and unpacking safety notes.
8.1 Problems
Problem
Control panel does not display
anything
Sintering chamber is not heated
after the program is started
Sintering chamber heats very
slowly
Selected and temperature is not
attained
Lifting table cannot be lowered
42
Possible cause
No power
Control panels defective
Error in program selection
Unit has no power
Defective heating element
Defective heating element or
thermal element
Insuffi cient heating power due to
insuffi cient voltage
Defective heating element or
thermal element
Temperature
inside
chamber is above 200 °C
Unit has no power
Defective motor
Potential remedy
Check connections and power cord
as well as the appropriate fuses
Notify service technician
Restart the program
Check connections and power cord
as well as the appropriate fuses
Notify service technician
Notify service technician
Notify service technician
Notify service technician
sintering
Allow to cool for below 200 °C
Check connections and power cord
as well as the appropriate fuses
Perform emergency lowering (see
Lifting table, emergency lowering)
and notify service technician)