EINHELL CE-BC 5 M LiFePO4 Manual De Instrucciones Original página 16

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
5.3.5 RECOND
Charging program with 1.5 A constant current
charging, used only for restoring the charging ca-
pability of lead acid batteries which have under-
gone exhaustive discharge and have a minimum
residual voltage of 3 V. This charging program is
not suitable for VRLA batteries (e.g. AGM or GEL)
and LiFePO4 batteries. Caution! Use only for
batteries which are free-standing and have been
taken out of the car; do not use for batteries while
they are installed in the car with a connection to
the car's electrical system. The higher charging
voltage could damage the electrical system. The
RECOND process must be checked every half an
hour and must never exceed a time of 4 hours.
Using the RECOND charging program
Connect the charger to a lead acid battery as
described in section 5.4 and check the char-
ging process every half hour.
After 4 hours at the latest, or as soon as you
hear the battery start to gas (bubble), remove
the charger as described in section 5.4.
5.3.6 12 V LFP
Max. 5 A charging current, microprocessor-
controlled and dependent on the charge status of
the battery. Charging program specially for lithium
iron phosphate (LiFePO4 / LFP) batteries which
are themselves equipped with a BMS (Battery
Management System). It is prohibited to charge
LiFePO4 / LFP batteries which have no BMS.
5.3.7 For (FORCE)
This charging program has a higher end-of-char-
ge voltage and a temporary charging current of 5
A. It is used only for restoring the charging capa-
bility of lead acid batteries which have undergone
exhaustive discharge and have a minimum resi-
dual voltage of least 1 V. This charging program
can be activated only without a connected battery
(see section 5.2.1).
The battery will be charged with 5 A for approx. 5
minutes. Then the battery should have a residual
voltage of more than 3 V. If this is the case, the
device will continue to charge the battery using
the "12 V STD" charging program. If this is not the
case, the LED will indicate "BAt". The battery is
defective.
Warning!
Follow the instructions supplied by the battery
manufacturer.
Only use for batteries which are free-standing
and have been taken out of the car, not while
they are installed in the car with a connection
GB
to the car's electrical system. The higher
charging voltage could damage the electrical
system.
Use the FORCE program only together with
a normal lead acid battery (wet / Ca/Ca bat-
teries).
Never use it for a battery of sealed design (a
VRLA battery such as an AGM or GEL bat-
tery) or for a lithium iron phosphate battery
(LiFePO4 / LFP).
Protection against swapped poles is not pro-
vided. If the poles are swapped there is a risk
of damaging the charger and the battery. It
is imperative to make sure that the polarity is
correct when you connect up.
5.3.8 Additional function SUPPLY
For supplying 12 V DC voltage, e.g. when chan-
ging a battery or for operating 12 V DC / max. 5
A consumers that are also intended for a motor
vehicle's 12 V connection.
Warning! Protection against swapped poles will
not be available. If the poles are swapped there
is a risk of damaging the charger and the battery/
on-board vehicle power supply or a connected
consumer. It is imperative that you make sure the
polarity is correct when you connect up. Observe
the maximum power consumption (see "Technical
data") of the consumer.
Note:
The direct voltage which is provided (shown
in the display) is load-dependent and without
load it is approx. 13.7 V.
This function can be used for consumers
which are operated from a vehicle's cigarette
lighter.
Refer to and observe the operating manual
for your 12 V consumer.
5.4 Charging the battery:
First connect the red charging cable to the
positive pole of the battery.
Then connect the black charging cable to the
bodywork of the vehicle away from the battery
and the petrol pipe.
Warning! Under normal circumstances the
negative battery pole is connected to the bo-
dywork and you proceed as described above.
In exceptional cases it is possible that the po-
sitive battery pole is connected to the body-
work (positive earthing). In this case, connect
the black charger cable to the negative pole
on the battery. Then connect the red charger
- 16 -
loading

Este manual también es adecuado para:

10.022.51