Pentair SL Serie Manual Del Propietário página 7

Idiomas disponibles

Idiomas disponibles

ELECTRICAL
MOTOR SWITCH SETTINGS
DISCONNECT POWER BEFORE WORKING ON PUMP, MOTOR,
PRESSURE SWITCH, OR WIRING.
NOTE: 1/3 and 1/2 HP motors are dual voltage and are factory set
to 115V 3/4 & 1 HP motors are also dual voltage, but are factory
set 230V. Motor terminal board (located under the motor end
cover) should look like that shown below. Use the instructions to
set your motor to match your power source.
Never connect a motor set to 115V to a 230 V power
source.
PLUG TYPE VOLTAGE SELECTOR
Voltage Change Plug
Ground Wire Connection
Figure 8: Voltage set to 230 volts, Plug Type
Voltage is factory set to 230 volts. To change to 115 volts:
1.
Make sure power is off.
2.
Pull the voltage change plug off of the tabs.
3.
Move the voltage change plug to the 115 volt position.
The plug will now cover 2 metal tabs and the arrow on the plug
will line up with the 115V arrow on the label
(see Figure 9).
Figure 9: Voltage set to 115 volts, Plug Type
P15004 (12-15-22)
Power Connections
Pressure Switch
4530
4.
Attach the incoming power leads to the two outer screws
on the pressure switch as shown in Figure 8.
5.
Attach the ground wire to one of the grounding
connections, shown in Figure 8.
6.
If there are other wires, they should be capped.
7.
Reinstall the Motor end cover.
Power Supply Connections
Voltage
Change
Dial
Ground Wire Connection
Figure 10: Voltage set to 230 volts, Dial Type
Voltage is factory set to 230 volts. To change to 115 volts:
1.
Make sure power is off.
2.
Turn the dial counter-clockwise until 115 shows in the dial
window as shown in Figure 11.
Figure 11: Voltage set to 115 volts, Dial Type
3.
Attach the incoming power leads to the two outer screws
on the pressure switch as shown in Figure 10.
4.
Attach the ground wire to the grounding connections as
shown in Figure 10.
5.
If there are other wires, they should be capped.
6.
Reinstall the Motor end cover.
Pressure Switch
7
loading