Cleaning; Calibrating - Stahlwille 701 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Cleaning

Cleaning
ATTENTION
Material damage possible due to
incorrect cleaning.
 Clean the torque wrench using a dry,
clean cloth only.

Calibrating

Apart from regular calibration, the torque wrench is
maintenance-free.
The internal components of the torque wrench are
subject to normal wear during use. The accuracy of
the torque wrench must therefore be checked at
regular intervals.
In the event of damage to the torque wrench or
malfunctions, repair with subsequent calibration is
necessary.
Repairs may only be undertaken by STAHLWILLE.
Returns to STAHLWILLE must always take
place without the lithium battery. If necessary,
return the torque wrench in its plastic case
without the lithium battery.
Calibration or adjustment of the torque wrench may
only be performed using a suitable calibration
device.
Torque wrenches are test equipment. The
calibration interval is dependent on the following
operating factors, etc.:
 Frequency of use
 Typical load during use
 Environmental conditions during the working
process
 Storage conditions.
The period of time for calibration arises from the
test equipment monitoring procedure defined within
24
your company (e.g. ISO 9000 ff). If test equipment
monitoring is not undertaken within your company,
have the torque wrench calibrated or adjusted after
a maximum of 12 months starting from initial use
(DIN EN ISO 6789).
If the fault code "5" is displayed after switching on
the torque wrench and the red LED flashes, the
torque wrench should be calibrated as soon as
possible according to the specifications of
DIN EN ISO 6789.
 To continue working, acknowledge the message
by pressing the operating button once.
 Have the torque wrench calibrated according to
the specifications of DIN EN ISO 6789 as soon as
possible.
Accessories for calibration
STAHLWILLE offers the following accessories for
calibrating and adjusting the torque wrench:
 Calibration and adjustment facility perfectControl
 7794-1 (torque)
 7794-2 (torque)
 7794-3 (torque and angle)
 Calibration facility Manutork
®
7791
®