Using the torque wrench

Proceed as follows to remove the socket:
 Press the green QuickRelease button (1).
 Pull out the socket (2).

Switching the torque wrench on and off

 To switch the torque wrench on, briefly press the
operating button.
The red LED lights up. The torque wrench vibrates.
The start logo is displayed. You can now
additionally display the serial number and other
data on the torque wrench. Proceed as follows to do
this:
 Press the operating button briefly whilst the model
number is displayed.
The following data are each displayed in succession
for approx. five seconds:
 Firmware version
 Serial number (S/N)
 Bootloader version
 Hardware version
After displaying the start logo or the additional
information, the torque wrench is automatically
tared. The taring symbol is displayed. Once taring is
completed, the battery's state of charge is displayed
for approx. two seconds. If the state of charge is
sufficient, the torque wrench is now ready to use.
The set function mode and the selected unit are
shown on the display. If the state of charge is not
16
sufficient, the corresponding symbol is displayed
constantly. In this case, replace the spent battery
with a new battery of the same type.
When the torque wrench is not in use, it
switches off after a specified period of time. A
shut-off time of 3 minutes is defined in the
factory. The shut-off time can be defined using
the SENSOMASTER software. Notes on the
SENSOMASTER software can be found in the
software instructions.
 To switch the torque wrench off manually, press
and hold the operating button.
After a short while, the taring symbol is displayed.
 Keep pressing the operating button.
The torque wrench is switched off approx. five
seconds after initially pressing.
Using the torque wrench
WARNING
Risk of injury due to incorrect torque
values.
 Make sure that the threaded
connection is tightened using the
correct torque value.
WARNING
Risk of injury due to unintentional
movement of the ratchet switching
lever.
 Prior to the bolting process, use the
switching lever to set the desired
working direction.
 Do not touch the switching lever
during the process.