Using the torque wrench
CAUTION
Risk of injury due to slipping.
Make sure you are standing securely
whilst using the torque wrench.
Ensure adequate freedom of
movement when using the torque
wrench.
CAUTION
Risk of injury due to overloading the
torque wrench.
End the tightening procedure when
the desired torque is shown on the
display.
ATTENTION
Damage to the measuring elements of
the torque wrench possible.
Protect the torque wrench e.g.
against hard jolts or dropping.
Switch the torque wrench on.
Select the desired unit for the torque.
Select the desired function mode.
Make sure that the socket is fastened correctly
and engaged securely on the torque wrench.
Only actuate the torque wrench using the handle.
Grip the handle centrally.
Tighten tangentially to the swivelling radius and at
right angles to the bolting axis.
Selecting units
The following units can be selected for the torque:
N‧m,
cN‧m,
ft‧lb,
in‧lb.
The unit N‧m is set in the factory.
Switch the torque wrench on.
The unit currently set for the torque is displayed.
Proceed as follows to change the displayed unit:
Press the operating button briefly three times in
succession.
The next possible unit is displayed and set.
Repeat pressing the operating button three times
until the desired unit is displayed.
The selected unit remains set even after switching
off.
17