Using the torque wrench
Working in "Track" function mode
In this function mode, the currently generated
torque is measured and shown on the display.
Whilst tightening, monitor the torque value on the
display.
Tighten evenly and without interruption in the final
phase until you see the desired target torque
value.
During the bolting process in "Track" function mode,
the following displays and signals are provided
depending on the settings which have been
undertaken:
The current torque value is displayed.
When you have reached 125 % of the nominal
torque value (overload), this is displayed:
The torque wrench noticeably vibrates at
intervals.
"Overload" is shown on the display.
The red LED flashes.
Several short beeps are audible.
Proceed as follows to display the last peak value
again:
Press the operating button once.
The last peak value is displayed.
To save the displayed value, press the operating
button a second time whilst it is displayed.
The value is saved. The green LED flashes once.
Each value can only be saved once.
Working in "Peak" function mode
During a bolting process, the current torque is
measured and the maximum torque value achieved
during it is shown on the display. This is the so-
called peak.
Whilst tightening, monitor the torque value on the
display.
Tighten evenly and without interruption in the final
phase until you see the desired target torque
value.
During the bolting process in "Peak" function mode,
the following displays and signals are provided
depending on the settings which have been
undertaken:
The peak torque value is displayed.
When you have reached 125 % of the nominal
torque value (overload), this is displayed:
The torque wrench noticeably vibrates at
intervals.
"Overload" is shown on the display.
19