The electrical hook-up must be performed ac-
cording to:
• absorbed power specifications indicated on
the machine data plate.
• the distance between the machine and the
electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when
starting up) of the rated voltage specified on
the data plate.
- The user must:
• Connect the machine to its own electrical con-
nection fitted with a suitable 30-mA current
sensitive circuit breaker
• Power line fuses in accordance with specifica-
tions in the main wiring diagram of this manual.
• Provide the workshop electric installation with
an efficient grounding circuit.
- Prevent unauthorised use of the machine,
always disconnect the power supply plug
when the machine is not used (switched off)
for extended periods of time.
- If the machine is connected directly to the
power supply by means of the main electrical
board and without the use of a plug, install
a key-operated switch or suitable lock-out
device to restrict machine use exclusively to
qualified personnel.
WARNING
A good grounding connection is essential for
correct operation of the machine. NEVER con-
nect the machine ground wire to a gas pipe,
water pipe, telephone cable or any other
unsuitable object.
COMPRESSED AIR
HOOK-UP
CAUTION
The compressed air hook-up may only be per-
formed if the pneumatic ring nut is supplied
(optional accessory supplied on request).
WARNING
All compressed air hook-ups must be carried
48
out by qualified personnel only.
- The hook-up to the workshop compressed
air system must ensure a minimum pressure
of 8 bar.
- The union for connecting to the compressed
air system is of a universal type and therefore
no special or additional couplings are
required. A pressure-resistant hose with 6mm
inner diameter and 14mm outer diameter
must be fixed to the notched union using the
hose clamp provided with the machine.
Non-compliance with the instructions and dan-
ger warnings can cause serious injuries to the
operator or other persons.
Do not operate the machine until you have read
and understood all the danger/warning notices
in this manual.
In order to operate the machine correctly, it is
necessary to be a qualified and authorised op-
erator, able to be trained and to know the safety
regulations. Operators are expressly forbidden
from using the machine under the influence of
alcohol or drugs capable of affecting physical
and mental capacity.
The following conditions are essential:
- read and understand the information and
instructions described in this manual;
- have a thorough knowledge of the features and
characteristics of the machine;
- keep unauthorised persons well clear of the
working area;
- make sure that the machine has been installed
in compliance with all relevant standards and
regulations in force;
- make sure that all machine operators are suit-
ably trained, that they are capable of using the
machine correctly and safely and that they are
adequately supervised during work;
- do not touch power lines or the inside of
EM 9550 Plus - EM 9550 C Plus - Operator's manual
SAFETY REGULATIONS
WARNING