Corghi EM 9550 Plus Manual De Uso página 71

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

- select the
programme;
- press the
button;
- when the selection is made, the "CAL ENT"
message is shown on the LCD display;
- fix the calibration template in correspondence of
the threaded hole located in the shaft assembly
bell using the M8 screw (A, Fig.30) supplied with
the ultrasonic sensor;
- use the locking device with a wheel spacer (ma-
chine version with automatic locking system)
or a cone and the wheel fixing nut to bring the
template in contact with the shaft assembly
bell (fig.30);
- press the
button to confirm the secur-
ing of the template;
- Once confirmed, "CAL rot" is shown on the LCD
display
- slowly turn the template towards the operator
to automatically enable the clamping brake
(fig.31);
EM 9550 Plus - EM 9550 C Plus - Operator's manual
- When template movement is complete, the
message "CAL CLO" will appear on the LCD
display
- slowly lower the wheel guard (fig. 32), the ma-
chine will automatically calibrate the sensor.
30
If the calibration has been performed success-
fully, an acoustic consent signal is emitted.
On the contrary, the display of the message A20
indicates that:
- the position of the calibration template during
the calibration phase is not correct. Therefore
position it correctly, checking that the ultra-
sonic sensor's emitter/receiver is in line with
the calibration template (see figure 32), and
repeat the procedure.
- the internal sensor was not in the rest position.
Position it to the rest position and repeat the
procedure.
31
32
UK
71
Tabla de contenido
loading

Este manual también es adecuado para:

Em 9550 c plus laserline

Tabla de contenido