9. The remaining end of the flat braided cable is terminated at the ground rod as indicated in the
10. On the rear cover of the panel-mount enclosure, connect the short black wire (provided) and
11. Connect the white, blue, red and black wires to the POWERCELL connector, as shown. (Refer to
Installation of the POWERCELL cable is now complete.
2.4.5.8.
PowerMount Cabling, Harsh Enclosure
Preparing the terminal for use with PowerMount tank and hopper systems involves two phases:
•
30205319
|
11
|
07/2019
vehicle scale's installation drawing.
the twisted black and green wires from the POWERCELL cable to the external ground stud with
a hex nut as shown in Figure 2-64.
Table 2-5 and Table 2-6)
Figure 2-65: POWERCELL Connector, Wired
Preparation of the cable and gland
Figure 2-64: Ground Wiring
METTLER TOLEDO IND570 Terminal Installation Manual
2-35