POWERCELL PDX Vehicle System Cabling, Harsh Enclosure
Preparing the terminal for use with POWERCELL PDX load cells involves three phases:
Each of these steps must be correctly completed to ensure the correct function of the POWERCELL
network.
2.4.5.6.1.
Cable and Gland Preparation, Harsh Enclosure
Ground and shield terminations are a critical part of the POWERCELL PDX system's immunity to
noise and electrical surges. Prepare and install the terminal end of the POWERCELL PDX home run
cable as follows – refer to Figure 2-39 and Table 2-4.
2-24
METTLER TOLEDO IND570 Terminal Installation Manual
Preparation of the cable and gland
External connection and grounding of the cable
Internal connection and grounding of the cable.
Figure 2-38: IND570 Harsh Enclosure, POWERCELL
Figure 2-39: POWERCELL Cable Preparation – Harsh
Table 2-4: Cable Preparation Lengths – Harsh
Letter
A
Length of cable jacket from outer braided shield
B
Length of inner braided shield and foil
Description
Length
25 mm (1.0 in)
25 mm (1.0 in)
30205319
|
11
|
07/2019