Mettler Toledo IND570 Manual De Instalación página 47

Ocultar thumbs Ver también para IND570:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 109
2. Depending upon the diameter of the cable to be installed, select one of the two different sized
3. When making cable terminations inside the harsh enclosure, ensure that the cable length from
4. After making the wiring connections as described in the next section, ensure the nut on the
5. Cable shielding should be grounded to the IND570's enclosure by spreading the shield wires
2-14
METTLER TOLEDO IND570 Terminal Installation Manual
rubber grommets (if required) to properly seal around the cable.
Grommet
None
Larger size hole
Smaller size hole
the terminal strip/connector to the terminal housing is sufficient so that no strain is placed on
the connector assembly when the housing is in the fully open position.
cable gland is tightened properly to seal around the cable. Ensure that this seal is watertight.
as shown at the top of Figure 2-23, then folding them back over the plastic component of the
cable gland before pressing it into the threaded body.
Figure 2-22: Cable Glands
Table 2-2: Grommet Cable Sizes
Cable Diameter
7–10 mm (0.28–0.39 in.)
5– 6 mm (0.20–0.24 in.)
3–4 mm (0.12–0.16 in.)
30205319
|
11
|
07/2019
Tabla de contenido
loading

Tabla de contenido