DNCKE−...−S / KEC−...−S
5.2.3
Make tubing connection to the clamping unit
In case of use in normal ambient atmosphere (without particles):
Remove the covers (if any) from the compressed air supply
ports.
Remove dirt particles or foreign matter in the ports and tubing
lines.
Use tubing lines that are as short as possible. This permits short
switching times.
Connect the tubing to the supply ports of the clamping unit 2
and, if applicable, to the supply ports of the cylinder 1 in
accordance with DIN EN ISO 4414.
Size
Supply port for clamping unit
Compressed air supply port for cylinder (only
DNCKE)
Tab. 4
If used in fine dusty or misty ambient air to prevent dirt particles
from entering the pneumatic system:
Use a barbed fitting (e.g. QS-CM-M5) instead of the filter nipple
in the exhaust channel 7 of the spring interior.
Guide hose into an area with clean ambient air.
Festo – DNCKE−...−S / KEC−...−S – 1511b English
KEC
Fig. 10
DNCKE
40
KEC
16
2
G 1/8
1
G 1/4
Fig. 11
2
1
DNCKE
63
100
20
25
G 1/4
G 3/8
G 3/8
G 1/2
7
39