Make tubing connection to the clamping unit

In case of use in normal ambient atmosphere (without particles):
• Remove the covers (if any) from the compressed air supply
ports.
• Remove dirt particles or foreign matter in the ports and tubing
lines.
• Use tubing lines that are as short as possible. This permits short
switching times.
• Connect the tubing to the supply ports of the clamping unit 2
and, if applicable, to the supply ports of the cylinder 1 in
accordance with DIN EN ISO 4414.
Size
Supply port for clamping unit
Compressed air supply port for cylinder (only
DNCKE)
Tab. 4
If used in fine dusty or misty ambient air to prevent dirt particles
from entering the pneumatic system:
• Use a barbed fitting (e.g. QS-CM-M5) instead of the filter nipple
in the exhaust channel 7 of the spring interior.
• Guide hose into an area with clean ambient air.
Festo – DNCKE−...−S / KEC−...−S – 1511b English
KEC
Fig. 10
DNCKE
40
KEC
16
2
G 1/8
1
G 1/4
Fig. 11
2
1
DNCKE
63
100
20
25
G 1/4
G 3/8
G 3/8
G 1/2
7
39