Technical Data - salmson SHS Serie Instalacion Y Puesta En Servicio

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
Non-electrical devices (e.g. hydraulics) also comply with EC
directive 94/09/EC.
Danger of explosion!
The housing of the hydraulics must be fully
submerged and flooded (completely filled
with the pumped liquid) during operation. If
the housing is not submerged and/or there is
air in the hydraulics, flying sparks may cause
an explosion e.g. due to static charge!
Ensure that dry-run protection is in place for
switching off.
4.3.1 Explosion coding
The Ex d IIB T4 explosion coding on the type plate indicates the
following:
- Ex = explosion-proof device complying to Euro norm
- d = ignition protection type for motor casing: Pressure-resis-
tant encapsulation
- II = intended for places where explosions may occur, with the
exception of mines
- B = intended for use with gases in sub-group B (all gases
excluding hydrogen, acetylene, carbon disulphide)
- T4 = max. surface temperature of the device is 275 °F
(135°C)
4.3.2 "Pressure-resistant encapsulation" protection type
Motors with this protection type are equipped with a tempera-
ture control system.
The temperature control system should be connected
in such a manner that, if the temperature limiter is trig-
gered, it can only be switched back on after the
release button has been manually activated.
4.4
Explosion protection certification number
- SHS 205...T4 (3~400 V/50 Hz): LCIE 03 ATEX 6202
- SBS 206...: LCIE 03 ATEX 6202
- SCA/SVO 206...: LCIE 03 ATEX 6202
4.5
Operating modes
4.5.1 Operating mode "S1" (continuous operation)
The pump can operate continuously at the rated load without
exceeding the maximum permissible temperature.
4.5.2 Operating mode "S2" (short-term operation)
The maximum operating period is given in minutes, for exam-
ple, S2-15. The pause must continue until the machine temper-
ature no longer deviates from that of the coolant by more than
2 K .
4.5.3 Operating mode S3 (interval operation)
This operating mode defines a combination of periods of opera-
tion and standstill. With S3 operation, the values given are
always calculated based on a period of 10 minutes.
Examples
- S3 20%
Operation 20% of 10 min ) 2 min/standstill 80% of
10 min = 8 min
- S3 3 min
Operation 3 min/standstill 7 min
If two values are given, they relate to each other e.g.:
- S3 5 min/20 min
Operation 5 min/standstill 15 min
- S3 25%/20 min
Operation 5 min/standstill 15 min
4.6

Technical data

General data
Mains supply:
Power consumption P
Rated motor capacity P
Max. pump head:
Max. pump flow:
Activation type:
Liquid temperature:
Protection class:
Isolation class:
Speed:
Max. submersion:
1)
Operating modes
Submerged:
Emerged:
Starts per hour
Recommended:
Maximum:
Explosion protection*
SHS 205...T4; SBS 206... :
SCA/SVO 206...T4 :
SCA/SVO 205... :
SHS 205...M; SCA/SVO 206...M :
Discharge port
SHS 205... :
SBS 206... :
SCA/SVO 205... :
SCA/SVO 206... :
Free flow diameter
SHS/SBS... :
SCA/SVO... :
* Explosion protection only with products with three-phase cur-
rent motor and without float switch!
1)
Maximum operating period: 200 h/a
35
see type plate
:
see type plate
1
:
see type plate
2
see type plate
see type plate
direct
3...35°C
IP 68
F
2900 rpm
10 m
S1 / S3 25%
S2-8 min
20/h
SHS.../SBS...: 50/h
SCA/SVO 205...: 70/h
SCA/SVO 206...: 40/h
Ex d IIB T4
-
-
Rp 2
Rp 2½
DN 50, PN 10/16
DN 65, PN 10/16
10 mm
44 mm
Tabla de contenido
loading

Tabla de contenido