Interpreting The Leds Of The Display; Maximum Programmable Values; Factory-Set Values; Visual Warnings - Orved Bright Serie Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

OPERATION

9.1.1 INTERPRETING ThE lEDS OF ThE DISPlAy

The six upper and lower LEDs provide an immediate graphical
indication on the current function, on the number of cycles per-
formed before the oil must be replaced, on the alarm status and
on the value set in relation to the maximum value that can be set.

9.1.2 MAXIMUM PROGRAMMABlE VAlUES

FUNCTION
VACUUM
ADDITIONAl VACUUM
SEAlING
GAS INjECTION
SOFTAIR *
* OPTION
WARNINGS!
• The difference between the value of the vacuum and the value of the gas must be 30%. Therefore, the ma-
ximum gas value that can be set – with a 99% vacuum value – is 69%
• The minimum sealing value is 1 second and therefore it cannot be reset.

9.1.3 FACTORy-SET VAlUES

The values can be changed or integrated via programming, in which case they are overwritten.
The factory settings can be restored at any time by resetting (§9.4.2 / pt.3)

9.2 VISUAl WARNINGS

The 12 LEDs and the two displays allow a number of useful messages relative to machine maintenance and safety to be
displayed (§ 9.1.1).
Upon the two displays, in addition to the functions inherent the performed working cycle, further more important in-
formation such as serial number, the number of cycles performed by the machine before changing the oil, the software
version installed displayed and/or can be recalled.
42
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
PROGRAMMABlE VAlUES
30 - 99%
0 - 120 sec
1 - 10 sec
0 - 30%
0 – 30 sec
Tabla de contenido
loading

Este manual también es adecuado para:

Bright 315Bright 12Bright 16Bright 18

Tabla de contenido