ADJUSTMENTS
NOTE: This adjustment is only required
if the type of gas to be connected is diff erent
from that used for testing, after the oven
burner air bushing has been replaced (see
page 20). Before making this adjustment,
check that the gas supply pressure is the
same as the rated pressure for the type of
gas in use (see table at back of manual).
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Remove the bottom plates (A) and the grid
2)
(B) from the oven.
Remove the rack (C).
3)
Undo the screws and remove the guard (D).
4)
Undo the locking screw (E).
5)
Set the bush (F) in contact at the distance
6)
shown in the fi gure.
Tighten the screw (E).
7)
Replace the panel (D) and the rack (C) on
8)
completion of the operation.
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Take out the screws (C) and take down the
3)
control panel (B).
Undo the screws (D) and extract the cap (E).
4)
Pull off the cone (F).
5)
Clean the cone (F) as well as its seat.
6)
Coat the cone with grease (F), fi t it in its seat
7)
and turn it a few times.
Pull off the cone (F) to remove the excess
8)
grease.
Replace the cone (F) and the cap (E).
9)
Replace the control panel (B) and the knob
10)
(A) on completion of the operation.
3301360_inst_GB_rev.2
ADJUSTING OVEN BURNER PRIMARY AIR
GREASING THE GAS TAP