ADJUSTMENTS
INSTRUCTIONS AND WARNING FOR ADJUSTMENTS
WARNING: Before making any type
of adjustment, activate all the safety de-
vices provided and decide whether staff at
work and those in the vicinity should be in-
formed.
In particular, turn off the gas supply tap, cut
off the electricity supply using the master
switch and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (TOP BURNERS)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Take out the screws (C) and take down the
3)
control panel (B).
Unscrew the nozzle (D) and replace it with
4)
the one suitable for the type of gas in use
(see table at back of manual).
Fully screw the injector.
5)
After making the setting, seal the screw with
6)
paint.
Replace the control panel (B) and the knob
7)
(A) on completion of the operation.
ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Take out the screws (C) and take down the
3)
control panel (B).
Unscrew the nozzle (D) and replace it with
4)
the one suitable for the type of gas in use
(see table at back of manual).
Fully screw the injector.
5)
After making the setting, seal the screw with
6)
paint.
Replace the control panel (B) and the knobs
7)
(A) on completion of the operation.
3301360_inst_GB_rev.2
ADJUSTMENTS
quired if the type of gas to be connected is
diff erent from that used for testing after the
conversion procedure has been carried out
(see pag. 13).
justments, check that the gas supply pressure
is the same as the rated pressure for the type
of gas in use (see table at back of manual).
NOTE: These adjustments are only re-
WARNING: Before making these ad-
C
A
C
B
C
A
C
B
ENGLISH
D
D
D
15