SAFETY
HAZARDS AND SAFETY PROVISIONS DURING APPLIANCE DECOMMISSIONING
When decommissioning the appliance, watch out for the following hazards and provide for the
countermeasures indicated below:
► Source of hazard: Electric power
Where or in which situations
Hazard
does the hazard occur?
Risk of electric
• On the power cable
shock caused by
• Under protective panels
live components
• Under the control panel
• Under protection covers
► Source of hazard: Handling of heavy loads
Hazard
Risk of injury due
to body overload
► Source of hazard: Risk generated by materials/substances
Hazard
Concentration
of
unburned gas emis-
sions due to an in-
correct
appliance
decommissioning
3301360_ut_GB_rev.2
Where or in which situations
does the hazard occur?
When the appliance moves
Where or in which situations
does the hazard occur?
During appliance decom-
missioning
Countermeasures
• Operations to the electric
system may be carried out
by authorised and qualifi ed
staff only, in accordance with
the relevant applicable laws.
• Specialist procedure
• Turn off the power supply
before removing the covers
• Secure it to prevent acciden-
tal switching on
• Ensure that there is no volt-
age
Countermeasures
• Use a suitable lifting
device
• Observe the limit values
for lifting and transport
• Wear personal protec-
tive equipment
Countermeasures
Decommissioning opera-
tions must be carried out
by qualifi ed personnel
ENGLISH
Safety device
• Protection
panels
• System
switch-dis-
connector
Safety device
• Protective
gloves
• Protective shoes
• Safety helmet (e.g.
for
suspended
loads,
overhead
operations...)
Safety device
None
13