Angelo Po 2N1FAGF Manual De Uso página 173

Idiomas disponibles
  • ES

Idiomas disponibles

SERVICING
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Take out the screws (C) and take down the da-
3)
shboard (B).
Undo the screw (D) of the pressure connec-
4)
tion.
Connect the pressure gauge (E) to the pressu-
5)
re test point (F).
Turn the gas supply tap back on.
6)
Light the burner and turn the knob to the full
7)
fl ame setting, then check that the pressure
reading complies with the values in the table
(see back of manual).
Turn off the burner, disconnect the pressure
8)
gauge.
See paragraph "TROUBLESHOOTING" of the
User instructions manual.
HANDLING AND INSTALLATION
INSTRUCTIONS AND WARNINGS FOR HANDLING AND INSTALLATION
NOTE: Read the following sections
carefully before performing any handling
and installation operations; read the
following sections of the "User instruction
manual":
– Hazards and safety provisions during trans-
port.
– Hazards and safety provisions during assem-
bly.
– Hazards and safety provisions during instal-
lation, commissioning, adjustments and part
replacement
WARNING: All handling and instal-
lation operations shall be carried out in ac-
cordance with current legislation on health
and safety at work.
3301360_inst_GB_rev.2
CHECKING GAS PRESSURE
Restore the initial conditions when the opera-
9)
tion is complete.
FAULT
TROUBLESHOOTING
If necessary, the person authorised to car-
ry out these operations should organise a
"safety plan" to protect the people directly
involved.
(water, electricity, and gas) must be set up
exclusively by suitably qualifi ed staff , in ac-
cordance with local requirements.
C