Ammann APR 4920 Traducción De Instrucciones Originales página 35

Ocultar thumbs Ver también para APR 4920:
Idiomas disponibles

Idiomas disponibles

3.5.2 Starting the Engine (Electrical start)
The oil pressure indicator (6) and charge indicator (4)
serve for monitoring the oil pressure and function of
the alternator.
Important
If one of the indicator lamps lights up during operation,
switch off the engine immediately, locate the fault and
have it rectified.
1
Set the engine speed lever (1) to full load (MAX).
6
5
Insert the ignition key (3) and turn to «I»; the charge indicator
(4) and the oil pressure indicator (6) lights up and a horn (5)
sounds.
Turn the ignition key (3) to «II» and release when the engine
starts.
The starting key must spring back to position «I»
and remain there during engine operation.
Attention
The charge (4) and oil pressure indicator (6)
should extinguish directly after the engine starts.
Prior to starting up again, the key has to be re-
turned to position «0».
B5399004.cdr
0
I
3
4
B5399009.cdr
If the engine starts:
MIN
1 – 2 min.
Set the engine speed lever (1) to idle (MIN).
Allow the engine to run for 1-2 minutes in order to warm up.
II
32
3. Operation
1
B5399008.cdr
loading

Este manual también es adecuado para: