3 Technical description
LED displays, string status
Constant green
light.
Flashing green
light.
Flashing red
light.
Constant red
light
Not lit.
14
LED displays, string status
(13)
(14)
(15)
(16)
3.2:
LED displays, string status
(13) Status display string 1/2
(14) Status display string 3/4
(15) Status display string 5/6
(16) Status display string 7/8
2 inputs at a time are grouped together using an integrated relay and are
activated/deactivated together. One LED indicator displays the string status
of 2 strings. For example, if there are only 4 strings, only the LED indicators
(13) and (14) are in operation.
The LED indicators light up or flash green or red. Note the following:
Direct solar irradiation can make the LED indicators difficult to read.
|
Meaning for the corresponding strings
Voltage of the relevant strings 300 V < U
|
Current of the relevant strings I < 20 A.
|
Auxiliary voltage supply (230 V
|
If DC disconnect is switched on (On):
Strings from SmartConnect are activated.
|
If DC disconnect is switched on (On):
Switch-on delay for the relevant strings, e.g. to protect the relay
|
contacts.
Relay is temporarily switched off. Temporary fault.
|
If a fault is no longer present:
The relay automatically reconnects.
|
Serious fault.
|
Relay is switched off.
|
Restart the device (see Chapter 10.1, page 67).
Voltage of the relevant string U
|
No auxiliary voltage supply (230 V
|
The DC disconnect is switched off (Off).
|
No strings connected.
|
< 1000 V.
DC
) is present.
AC
< 300 V.
DC
).
AC