Fault indicator
SMU status: Software I2
High
SMU status: Software I2 Low
SMU status: Software I
Total High
SMU status: Software I
Total Low
Relay switching delay
active
Switch-on delay active
Childlock delay active
SmartConnect
Operating manual
Meaning
Notice of a temporary fault.
|
One of the strings has exceeded
|
the current threshold value.
Notice of a temporary fault.
|
The reverse current limit value
|
has been exceeded by one of the
strings.
Notice of a temporary fault.
|
The sum total of the strings has
|
exceeded the limit value.
Notice of a temporary fault.
|
The sum total of the reverse
|
current value of the strings has
exceeded the limit value.
The switch-on delay after the
|
relay is switched off is active.
The switch-on delay after a
|
software threshold value has
been exceeded or after the
external string switch-off system
has been activated is active.
The switch-on delay following
|
too frequent operation of the
external string switch-off system
is active.
9 Help in the event of faults
Action
Check the fault message for the
|
SMU.
Check the dimensioning and
|
conductivity of the strings.
When no further fault is present,
|
the strings are reconnected.
Check the fault message for the
|
SMU.
Check the dimensioning and
|
conductivity of the strings.
Check the strings for short
|
circuits.
When no further fault is present,
|
the strings are reconnected.
Check the fault message for the
|
SMU.
Check the dimensioning and
|
conductivity of the strings.
When no further fault is present,
|
the strings are reconnected.
Check the fault message for the
|
SMU.
Check the dimensioning and
|
conductivity of the strings.
Check the strings for short
|
circuits.
When no further fault is present,
|
the strings are reconnected.
Wait. If there is no longer any
|
fault, the relay switches itself
back on.
Wait. If there is no further fault
|
and the voltage is present at the
series terminals FS:K1, the relay
is automatically reconnected.
If the relay does not reconnect
|
after the switch-on delay time
has elapsed, check the voltage
at the series terminals FS:K1.
Wait. If there is no further fault
|
and the voltage is present at the
series terminals FS:K1, the relay
is automatically reconnected.
If the relay does not reconnect
|
after the switch-on delay time
has elapsed, check the voltage
at the series terminals FS:K1.
65