Motorola IMPRES 2 Guia Del Usuario página 34

Ocultar thumbs Ver también para IMPRES 2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 144
Table 16: Status Indications of a Lithium-Ion Battery Prepared for
Shipment - IMPRES 2 or IMPRES Battery is due for Calibration (Cont.)
Status
Fault
• Battery is not making
proper electrical contact
with the charger.
• Battery is Unknown or
Nickel.
• An unknown condition is
preventing the battery
from being discharged.
• Charging is completed
before the Ship Lithium
goal is reached.
• The charger pocket is a
special type.
Standby
• Battery is waiting to rapid
charge.
• Battery is too hot, too
cold, or low voltage.
• Charger is too hot.
Note:
• The following messages are introduced in software version V1.05:
- Ship LI Discharge, xxx% Rated Capacity
- Ship LI Charge, xxx% Rated Capacity
- LI Ready to Ship, xx% Rated Capacity
- Cannot Discharge, for LI Shipment
- Ship Incomplete, Low Capacity:yy%
• The following messages are introduced in software version V1.11.01:
- Wrong Batt Type, Cannot Ship LI
- Radio Pocket, Cannot Ship LI
- Charging Pocket, Cannot Ship LI
Charger Display
WARNING:
NOT CHARGEABLE
REMOVE& REINSERT
OR
WRONG BATT TYPE
CANNOT SHIP LI
OR
CANNOT DISCHARGE
Flashing Red
FOR LI SHIPMENT
OR
SHIP INCOMPLETE
Low Capacity:yy%
OR
RADIO POCKET
CANNOT SHIP LI
OR
CHARGING POCKET
CANNOT SHIP LI
WARNING:
HOT BATTERY
WAITING TO CHRGE
OR
COLD BATTERY
Flashing Amber
WAITING TO CHRGE
OR
VERY LOW BATTERY
WAITING TO CHRGE
OR
HOT CHARGER
WAITING TO CHRGE
31
LED Indicator
loading