Motorola IMPRES 2 Guia Del Usuario página 28

Ocultar thumbs Ver también para IMPRES 2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 144
Unknown Battery
Some unknown batteries may not be detectable by the charger.
Unknown batteries do not declare charging parameters in a manner
recognizable by the charger. If an unknown battery is detected, then
the charger indicates charging as summarized in Table 12.
Table 12: Charging Indications for Unknown Batteries
Status
Charger Powers On
Battery Detected
Rapid Charging
Nearly Charged
• Battery Capacity
Unknown
Charged
• Battery Capacity
Unknown
Fault
Standby
• Battery is waiting to rapid
charge.
• Battery is too hot, too
cold, or low voltage.
• Charger is too hot.
Charger Display
Green for approximately
IMPRES 2
1 second
CHARGER
Steady Red
UNKNOWN
BATTERY
Steady Red
RAPID CHARGE
Flashing Green
TRICKLE CHARGE
Steady Green
CHARGE COMPLETE
WARNING:
Flashing Red
NOT CHARGEABLE
REMOVE & REINSERT
WARNING:
HOT BATTERY
WAITING TO CHRGE
OR
COLD BATTERY
Flashing Amber
WAITING TO CHRGE
OR
VERY LOW BATTERY
WAITING TO CHRGE
OR
HOT CHARGER
WAITING TO CHRGE