Thermo King V-200s Serie Manual De Instrucciones página 60

Tabla de contenido
NAME
dAL
Out of range alarm
Progammable from 1º up to 10º or off (0). When the difference between the return air temperature and the set point exceeds the on-screen return air temperature
reading flashes.
HC
Hour Counter initial value for maintenance purposes
(Tens of hours, e.g. 150=1500 hours), programmable from 1000 up to 5000, 500 steps.
dSP
Doors Switches Presence/Polarity
0: normally closed, 1: normally open, 2: not present.
bE
Buzzer Enable
0: not enabled, 1: enabled, 2: enabled also when keys are pressed, 3: enabled only when keys are pressed.
tu
Thermostat units
C: temperature visualization in ºC, F: temperature visualization in ºF.
Pu
Pressure units
b: pressure visualization in bar, P: pressure visualization in psi
trE
Temperature display resolution
0: whole; 1: resolution 0.5; 2: resolution: 0.1
In-Cab Control Box
DESCRIPTION
Eng
DEFAULT
MIN
MAX
0
0
10
150
0
500
1
0
2
2
0
3
C
C
F
P
b
P
0
0
2
33