Safety Devices; Interior Overpressure Protection; Excess Of Pressure Protection In Dimple Jacket; Important - Airplane VCR 1002 Manual De Instrucciones Y Mantenimiento

Reactor para cremas; tanque fusor
Tabla de contenido
Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

2.4 SAFETY DEVICES

2.4.1

Interior Overpressure Protection

The vessel has a rupture disc to protect against an overpressure inside, which is in
contact with internal atmosphere. In case of overpressure due to an abnormal
operation of the system that exceeds the nominal pressure of rupture disc, it breaks
down and depressurizes the vessel.
Interior pressure in vessel is always visible by a pressure gauge located in the top of
the vessel.
To ensure the properly operation of the rupture disc, the pressure inside
the vessel must not exceed the maximum pressure PS (3 bar). So, it may
be necessary the installation of pressure reducer elements which will
ensure that the supply pressure is lower than the design pressure.
The user must ensure that these elements are always in perfect operating
conditions.
2.4.2

Excess of pressure protection in dimple Jacket

The vessels' double jacket is equipped with internal overpressure protective
equipment consisting of a safety valve and a pressure gauge.
In case of overpressure exceeding the safety valve's nominal pressure, the valve
would open, thereby relieving the excess pressure inside the vessel's double jacket.
To ensure the properly operation of the security valve the pressure inside
the vessel must not exceed the maximum pressure PS (3 bar). So, it may
be necessary the installation of pressure reducer elements which will
ensure that the supply pressure is lower than the design pressure.
The user must ensure that these elements are always in perfect operating
conditions.

IMPORTANT

The relief outlet must be leaded to a safe area out of the reach of any
person.
2.4.3

Emergency Stop

The system has an EMERGENCY STOP BUTTON located in the control panel, which
stops immediately the equipment when it is pressed.
After an emergency stop, it is necessary to reset the button by turning it on its axis.
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
Client:
UNIPHARMA
Date:
11-2015
EN
ES
MDI VCR (v1.0)
8 of 153

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Met 0400721021-70-1721021-70-3

Tabla de contenido