Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
9.6.2
OVERVIEW screen (Process / Recipe)
Overview screen allows the visualization and control of equipment and also the
execution of load recipes
The equipment has two operating modes: Process and Recipe.
The screen has an operation selection and control panel at the top. The reactor's
picture will show the current state of every parameter and the values of the set
points.
To display the details on the temperature control skid (position and active valves,
enable circuit...), just press the skid box and it will enlarge.
VESSEL PARAMETERS AND OPERATIONS
The reactor has the following configurable parameters and operations in both the
Process and the Recipe mode:
Configurable parameters
Time
SP Mixer
Homogeniser
SP Homogeniser
Temperature VCR
VCR Vacuum
Dosification
SP Dosification
Temperature Fuser
SP Mixer Fusor
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
(see section 9.6.3. for loading recipes details)
Desired operation time
Speed and direction of rotation of the anchor stirrer
Start/Stop homogeniser
Speed of the homogeniser
Desired temperature inside VCR reactor
Vacuum pump start/stop
Product selection: PW/GCL/GCR
Desired dosing volume
Desired temperature inside MET tank
Speed of the melting tank's mixer
Client:
UNIPHARMA
Date:
11-2015
EN
ES
MDI VCR (v1.0)
50 of 153