Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
4.2.8
Venting system
The equipment has a sterile and permanently hydrophobic venting filter with a
stainless steel housing, located at the top of the vessel, with a porosity of 0,2 µm,
that ensures its sterility and prevents microbiological contamination inside the
vessel.
VENTIG FILTER WITH HOUSING
Brand:
Cartridge model:
Pore dimension:
Housing model:
Housing material:
Connections:
Units:
In the venting filter nozzle there is a diaphragm valve which allows the venting
operation when opened and the pressurize operation and vacuum when closed.
VALVE
Brand:
Type:
Model:
Materials:
Connections:
Dimensions:
The filtering groups must not be used with liquids incompatible with the
construction material, including cleaning agents. Incompatible materials
are those that chemically attack, soften, create cracks from pressure or
adversely affect construction materials in any way. Users must verify the
compatibility of the liquids used before using them.
The user is responsible for verifying the actual operation conditions to
ensure that the group is compatible with the application and local safety
regulations.
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
MILLIPORE
Aervent (CTGR75S01)
0,20 µm
S3000 (H1UV7S5G1HPP)
316L Stainless steel
Clamp ASME-BPE 1 ½''
1
Bürkert
Diaphragm manual
3233
Body: 316L stainless steel
Diaphragm: EPDM
Clamp ASME BPE 1 ½''
DN 40
Client:
UNIPHARMA
Date:
11-2015
EN
ES
MDI VCR (v1.0)