OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
The barrier fluid is water containing 5% of propylene glycol.
The pressure in the seal circuit should exceed by approximately 2bar
the working pressure in the pump's chamber.
For information on the barrier fluid's characteristics and the filling
conditions,
"Manufacturer Manuals" section.
Safety Devices of Barrier System
Barrier system has the following safety devices to ensure the proper operation of
the mechanical seal's cooling system.
There is a temperature probe that allows the control of barrier system's
temperature and, in case of detecting an excessive temperature, enables
automatically the passage of cold water through the barrier system or, in case of
detecting maximum temperature, the equipment is stopped automatically.
TEMPERATURE PROBE
Brand:
Type:
Model:
Measuring range:
Probe diameter:
Material:
Connection:
To ensure that the barrier system has enough pressure for its operation, there is a
pressure gauge with switch contacts, for fluid pressure visualization in barrier
system. In case of detecting a pressure under the set pressure, the equipment is
stopped automatically.
PRESSURE GAUGE WITH SWITCH CONTACTS
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
please
refer
to
WIKA
Pt100; Class B
TR10-C+T19
0...+140 ºC
Ø 3 mm
Stainless Steel AISI 316L
G ½''
Brand:
Model:
Measuring range:
Material:
Connection:
Client:
the
homogeniser's
WIKA
PGS23.100
0 - 10 bar
Stainless Steel AISI 316L
Rosca G ½''
Date:
11-2015
UNIPHARMA