Operating the Pump in Flow Mode

When connected to an inline 4-20mA flowmeter, this
pump is capable of maintaining a constant flow based on
the needs of your pool system.
Connecting a flowmeter and operating the pump in flow
mode will require the purchase of:
• Digital Input Wiring Kit (P/N 353129Z - Almond)
or RS-485 Automation Wiring Kit (P/N 356324Z -
Black).
Flow mode operation is not possible if controlling the pump
via RS-485.
A 4-20mA Flowmeter (Pentair recommends P/N
97014-4203KIT)

Flow Mode Setup and Configuration

Before beginning flow mode setup and configuration,
ensure the pool filter has been backwashed and all
pump and skimmer baskets are free of debris.
1. Press Start/Stop to stop the pump.
2. Following the installation instructions given in
the flowmeter's installation guide, install an inline
4-20mA flowmeter into the plumbing.
3. Using the Digital Input Wiring Kit, wire the flowmeter
to the pump's digital input port. See Figure 18A.
Note: Flow mode is not compatible with external
control via RS-485. However, a flowmeter can still
be connected. See Figure 18B.
Figure 18A
FLOWMETER
DIGITAL INPUTS
Figure 18B
FLOWMETER
DIGITAL INPUTS
4. Press and hold Display for 3 seconds.
5. Press Display three (3) times to access the Speed
or Flow mode selection screen. "Spd" will display.
XF
®
WHISPERFLO
VS and MAX-E-PRO
Digital Input Wiring Kit
(P/N 353129Z - Almond)
RED
+24V OUTPUT FOR D.I. TRIGGER
GREEN
SPEED 1 DIGITAL INPUT
YELLOW
SPEED 2 DIGITAL INPUT
ORANGE
SPEED 3 DIGITAL INPUT
BROWN
QUICK CLEAN DIGITAL INPUT
BLACK
GROUND
RS-485 Automation Kit
(P/N 356324Z - Black)
RED
+24V OUTPUT FOR D.I. TRIGGER
YELLOW
NOT USED
GREEN
NOT USED
WHITE
SPEED 1 DIGITAL INPUT
BLUE
SPEED 2 DIGITAL INPUT
ORANGE
SPEED 3 DIGITAL INPUT
BROWN
QUICK CLEAN DIGITAL INPUT
BLACK
GROUND
XF
®
VS Commercial Variable Speed Pump Installation and User' s Guide
Flow Mode Setup and Configuration
6. Use "+" and "-" to scroll to "Flo". See Figure 19.
Note: This option will not be available unless a
4-20mA flowmeter is connected to the pump.
FLo
Figure 19
7. Press Display. The Flow Mode High Speed
screen.
8. Use "+" and "-" to set a high speed for flow mode
between 2000 and 3450 RPM.
9. Press Display. "Press Start" will scroll across the
screen.
10. Press Start/Stop. The pump will ramp up to the
programmed maximum speed, then "Config Flo
Sensor" will scroll across the screen.
11. At the flowmeter, configure the flowmeter:
K Factor: Refer to flowmeter manual
Averaging: 10-30 (20 is recommended)
Sensitivity: Refer to flowmeter manual
4-Set: 0 GPM
20-Set: GPM displayed while pump motor is at
maximum speed set in step 8.
Note: Flowmeter configuration will timeout at the
drive after 10 minutes. If this occurs, repeat steps
4 through 10.
Note: The flowmeter 20-Set will need to be
reconfigured each time the system's filter is
cleaned.
- Continue to next page -
(cont.)