■ Ceiling-Mounted Type (T Type)
3-13. Required Minimum Space for Installation and Service
(1) Dimensions of suspension bolt pitch and unit
Length
GB
A
Type
12, 16, 18
855
25
1125
FR
36, 48, 60
1540
DE
IT
(2) Refrigerant tubing • drain hose position
Left side
PT
GR
251
Closed with rubber stopper at time of shipment.
ES
(3) Unit opening position (Refrigerant tubing • drain hose • power inlet port • remote controller wiring inlet port)
Left-side drain hose
outlet port
*3
Remote
controller wiring
inlet port
(ø30, knock-out)
*1
Side panel
Outside air intake duct connection port
*3
(ø100, knock-out)
Remote controller wiring
inlet port
(ø30, rubber grommet on
right side only)
DC̲Inverter̲Eng.indd 28
DC̲Inverter̲Eng.indd 28
B
C
910
210
1180
210
1595
210
Unit: mm
27.5
Rear (Figure shows view from front)
84
Left drain position
123
Top outlet port
Power inlet port
(ø40, knock-out)
Knock-out
Rear outlet port
Power inlet port
(ø40, knock-out)
Rear tubing hole
Left-side drain
84
hose outlet port
B
Ceiling side
A
(Suspension bolt pitch)
Fig. 3-33
75
97
Liquid
tubing
Gas tubing
146
Right drain position
Fig. 3-34
216
110
76
*2
1 Use a compass saw, jig saw or
*
*2 If the optional drain up kit is installed,
262
125
72
*3 If the remote controller wiring inlet
347
Unit: mm
Fig. 3-35
28
C
Air intake
Air
27.5
Unit: mm
Right side
216
(Liquid tubing •
Gas tubing)
161
251
Unit: mm
Right-side drain
hose outlet port
*1
Side panel
Position of plate
inside side panel
similar tool and cut along the
indented portion of the side panel.
this becomes the upper tubing outlet
port.
For details, refer to the manual for
the optional part.
port is changed to the left side
or the left top side, relocate the
rubber grommet to the left side. Use
aluminum tape or similar material to
seal the unused inlet port on the right
side.