Connection Diagram - Sanyo SPWXDR124GH56A Manual Del Usuario

Tabla de contenido
11-14. Wiring the Separate Receiver Unit
* Use wires that are 0.5 mm
* The wiring length must not exceed 400 m.
<Flush Mounting>

Connection diagram

Indoor unit
remote controller
terminal board
Wire of receiver unit
Provided
(field supply)
wire joint
(WHT 2)
Power wire from
receiver unit
Wire joint
CE-1 (provided)
<Exposed Mounting>
Connection diagram
Indoor unit
remote controller
terminal board
Use the remote controller cord (optional) for wiring
the separate receiver unit.
1. For the methods used to install the remote
controller cord, refer to "For flush mounting into a
wall, install the separate receiver unit in a metal
switch box (field supply) that has been recessed
into the wall in advance".
2. When using the remote controller cord (optional),
refer to the instruction manual that came with the
cord.
Check the terminal number on the indoor unit
before wiring the remote controller and be sure not
to wire incorrectly. (The unit will be damaged if high
voltage, such as 220 – 240 V AC, is applied to it.)
DC̲Inverter̲Eng.indd 113
DC̲Inverter̲Eng.indd 113
2
2
– 2 mm
in diameter.
Wire of receiver unit
(field supply)
1
2
Connector
1. Strip the insulation to approximately 14 mm
from the ends of the wires to be connected.
2. Twist together the 2 wires and create a
crimp connection at the wire joint.
3. If a special crimping tool is not used, or if
the connection is soldered, insulate the
wires using insulation tape.
1
2
Remote controller cord (optional)
113
WHT
1
Separate
BLK
2
receiver unit
Power wire from
receiver unit
WHT
1
Separate
BLK
2
receiver unit
GB
FR
DE
IT
PT
GR
ES
2007/07/25 13:21:56
2007/07/25 13:21:56
Tabla de contenido
loading

Tabla de contenido