When 1 indoor unit is operated with 2 remote controllers:
(The indoor unit runs according to which of the remote controllers is assigned as the main or sub unit.)
Control unit
Remote controller
terminal board
When several groups of indoor units are operated with 2 remote controllers:
(The remote controller (main or sub unit) can operate with any indoor unit.)
Remote controller
terminal board
11-10. How to Use the Test Run Setting
1. Set DIP switch [S003] No. 1 on the wireless
receiver unit PCB from OFF to ON.
2. All indicator lamps in the display section blink
during test run operation.
3. No temperature control is available during the test
run.
4. After the test run, be sure to reset DIP switch
No. 1 back to the OFF position and check that no
indicator lamps are blinking. Then remount and
attach the PCB cover as before.
NOTE
To avoid placing excessive operating load on the
equipment, use this function only when conducting
the test run.
The unit does not receive remote controller sig-
nals for approximately 1 minute after the power is
turned ON. This is not a malfunction. (The signals
are received, but have no immediate effect.)
DC̲Inverter̲Eng.indd 109
DC̲Inverter̲Eng.indd 109
Wireless receiver unit
Wired remote controller
*
(main)
(optional)
CN1
1
2
1
2
Indoor
unit
Ground
Wireless receiver
unit
Remote control
*
(main)
wiring among the
(optional)
Receiver
control groups
CN1
unit
(field supply)
1 2
1
2
1
2
Indoor
Indoor
unit No. 1
unit No. 2
Ground
Ground
* Use field wiring cables with a
cross-sectional area of at least
(sub)
*
0.5 mm
(optional)
* The maximum total length of
crossover cables must be no
1
2
longer than 400 m.
Remote control wiring (field supply)
Wired remote
* Use field wiring cables with a
controller
cross-sectional area of at least
(sub)
*
0.5 mm
(optional)
* The maximum total length of
1 2
crossover cables must be no
longer than 200 m.
1
2
1
2
Indoor
Indoor
unit No. 3
unit No. 4
Ground
Ground
Fig. 11-11
109
2
2
to 2 mm
.
2
2
to 2 mm
.
S003
Bit 1: OFF ON
Fig. 11-12