7.
Disconnect the 2off Fast-on terminals from the Gun Switch
8.
After removing the Gun Switch and Trigger, remove 1off self tapping screw
(M3x8) and detach the Gun Bracket.
9.
Remove the flange nut (M3) to remove the Pipe Clip and Sleeve.
10. Separate the Fibre Holder into two parts, and remove them from the Fibre-Optic.
Remove the Gun Harness Assy together with the O-ring, Fibre-Optic and Flexible
Hose.
11. Reassemble in reverse order.
Gun Bracket
Fast-On Terminals
Note: The tie wraps on the Gun Harness Assembly should be installed so that
they come in contact with the gun bracket, as shown in the diagram
below.
Note: Install the Fibre Optic Holder by aligning the marking on the holder with
the marking on the gun body (L).
It is recommended that Threadlock, (part No 95000006), is applied to the
cap bolt (M3x20), cap bolt (M3x8), and 2off hex nut (M3) when
reassembling the gun harness assy
Self tapping screw
(M3x8)
Sleeve
(M3x8)
Trigger
Gun Switch
O-Ring
Tie Wrap
(see 8-14-2 page 79).