3.
Remove 4off torx screws (M5x12) from the Joint Assy and remove the Joint Cover.
4.
Atach the Joint Assy in place on the Monitor Cabinets and secure with the previously
fitted flange socket bolts (M8x40) and two further supplied flange socket bolts
(M8x40).
5.
Pull out the wiring harnesses from the Monitor Cabinets.
6.
Connect the connectors and Earth connector.
Joint Cover
Joint Assy
Flange socket bolts (M8 x 40)
Wiring diagram
7.
To disassemble follow the procedure in reverse.
Torx screws (M5 x 12)
Earth connector
Connectors
CROSS PC board
Flange socket bolts (M8 x 40)
Connectors
39