Bezzera ARCADIA DE BREWING PROFILE Manual De Instrucciones página 60

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 105
BEZZERA ARCADIA BREWING PROFILE
MOD.
Problem
The coffee dosing switch flash-
es once selected
All lights of the keypad are
flashing, the coffee maker is
completely blocked
No coffee is dispensed
Coffee deposits on the bottom
of the cup
This Instruction Manual is an original publication issued by G. BEZZERA S.R.L. An authorised copy
of this manual can be requested by going to the WEB site: www.bezzera.com in the contact section.
Troubleshooting/
Solution
The set dose of coffee is not fol-
lowed, and the output is continu-
ous.
1 - Check if the mains water is
working and if the tap con-
nected to the mains is open.
2 - The fault is due to the lack of
water inside the boiler
No coffee is dispensed and the
key for the selected dose is flash-
ing.
Possible causes:
1 - the coffee is ground too finely.
2 - the filter holder is dirty inside
or the filter is damaged.
3 - The grinding discs are worn.
4 - High pump pressure (> 10bar
- 1 MPa).
60
Advice
Contact a specialised techni-
cian.
For point 1, do the checks.
For point 2, call a technician.
Select the coffee dosing key,
without the filter-holder, and
check that the water flow is con-
tinuous.
If the flow is continuous, the
problem is:
a) the coffee is ground too
finely;
b) the filter-holder is clogged.
In this case, immerse it in hot
water with specific detergent
tablets.
For any other problem, contact
a specialised technician.
Case 1 can be solved by adjust-
ing the grinder correctly.
In case 2, clean the filter holder
or replace the filter.
In cases 3-4, contact a techni-
cian.
loading