• the supply lines of the electric energy should meet the requirements of power
power supply
• check that the power line:
Automatic
safety switches
• protect the upstream cabinets with omnipolar circuit breakers with suitable
• instruct the operator on the position of the switches to be reached quickly in
Before
connecting
• consult the wiring diagrams annexed to the counter
• ensure that the rating plate data matches the characteristics of the electrical
• check that power supply voltage is the one reported on the rating plate
• remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
• proceed with wiring
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protection devices; modify the system to differentiate the start-up of
the various devices.

15. Checking and adjusting the temperature

the cooling temperature is controlled by means of:
digital solar thermometer (Fig.13); the electronic controller (optional) (Fig.12)
i
To change the controller programming, call the manufacturer.
42
Customer
provide a power line to the counter connection point.
Installer
provide the anchoring devices for all the wires in input and out-
put to/from the counter.
Manufac-
ARNEG S.p.A. denies all liability with respect to the user or third
parties for:
turer
- damage caused by failures or malfunction of the systems
installed upstream of the counter
- damage to the counter due to causes arising directly from
malfunction of the electrical system
consumption of the cabinet chap.9.
- has wires with suitable cross section
- is protected against over-current, overload and dispersions toward earth in
accordance with the rules in force
- for power lines longer than 4-5 m use cables with suitable cross-section.
i
The replacement of the damaged power cord is reserved to the manu-
facturer or a body authorised by the same.
DANGER! Live parts. Short circuit. Electrocution
The automatic circuit breakers must be such that they do not open the
circuit on the neutral, without simultaneously opening on the phases
and, in any case, must allow complete disconnection in conditions of
category III overvoltage
characteristics that will also function as master switches to section off the line
case of EMERGENCY
DANGER! Live parts. Short circuit. Electrocution
Check that the attachments of the lighting systems (floors, roof, ceil-
ing) are properly inserted and locked into their housings to avoid
disconnections during cleaning and maintenance operations, that may
cause harmful electric shocks.